Jacketing Board

ThermoWool Jacketing Board is a high-performance insulation solution designed for thermal insulation, soundproofing, and fire protection in plastered exterior insulation systems. It enhances thermal comfort, reduces heat loss and gain, improves energy efficiency, and prevents
condensation, making it an ideal choice for modern construction.

Key Features

✅ Advanced Thermal Insulation: Effectively minimizes heat transfer, reducing energy costs and enhancing indoor comfort.

✅ Superior Soundproofing: Provides excellent acoustic insulation, helping to reduce external noise pollution.

🔥 Fire-Resistant Composition: Made from non-combustible stone wool, ensuring high fire safety standards.

💧 Moisture & Condensation Control: Prevents water absorption, reducing the risk of mold and structural damage.

🛠️ Durable & Long-Lasting: Maintains its performance over time, resisting compression and deterioration.


Engineered for Jacketing Systems

Produced as an uncoated stone wool board, ThermoWool is specifically designed to integrate
seamlessly into jacketing systems, including insulation materials, adhesives, plasters, reinforcement meshes, and
surface coatings. It meets international mineral wool standards (EN 13162), ensuring top-tier performance in
thermal regulation, sound control, and fire safety.

Ideal for residential, commercial, and industrial buildings, ThermoWool Jacketing Board is the
reliable choice for achieving sustainable, energy-efficient, and safe construction.

Technical Information

Technical Characteristic Symbol Indicator Unit Declared Value Tolerance Standard
Material MW MW - Mineral Wool - EN 13162
Density ρ - kg/m³ 120 | 150 ±10% EN 1602
Length l l mm 1200 ±2% EN 822
Width b b mm 600 ±1.5% EN 822
Tensile Strength Perpendicular to Surface σmt TRi kPa min. 10 - EN 1607
Compression Stress at 10% Deformation σ10 CS(10/Y)i kPa ≥ 25 | ≥ 35 | ≥ 45 - EN 826
Thermal Conductivity λD - W/mK max 0.037 - EN 12939/12667
Thermal Resistance RD - m²K/W 0.83 | 1.11 | 1.39 | 1.67 | 1.94 | 2.22 | 2.78 | 3.33 | 3.88 | 4.25 - EN 13162
Thickness dN dN mm 30 | 40 | 50 | 60 | 70 | 80 | 100 | 120 | 140 | 150 - EN 823
Thickness Tolerance Class - mm T4 -3% or -3 mm / +5% or +5 mm EN 823
Dimensional Stability ∆Ɛd DS(70-) % max 1 - EN 1604
Water Vapour Permeability µ MU - 1 - EN 12086
Fire Reaction Class RtF - - A1 - EN 13501
Air Flow Resistance Afr Afr - NPD - EN 29053
Flatness Smax Smax mm S6 - max 6 mm - EN 825
Squareness Sb Sb mm/m S5 - max 5 mm/m - EN 824
Short-Term Water Absorption WS WP kg/m² ≤1 - EN 1609
Long-Term Water Absorption WL(P) WLP kg/m² ≤3 - EN 12087
Max. Usage Temperature - - °C +750 - -
Packaging Material - - - PE Film - -
Covering - - - Uncoated - -