Roof Mattress

ThermoWool Roof Mattress is a versatile insulation solution used in various roofing applications. It is suitable for cradle roofs, hipped roofs, snap roofs, and unutilized attic flooring. This product is also ideal for use between utilized roofs, rafters, or in horizontal installations without load. Additionally, ThermoWool Roof Mattress is perfect for metal and sandwich roofs, providing outstanding heat, sound, and fire insulation. It helps enhance the thermal efficiency of roofs, ensuring comfort, safety, and energy savings.

Key Features

✅ Advanced Thermal Insulation: Reduces heat loss, improves energy efficiency, and ensures optimal comfort in buildings.

✅ Excellent Soundproofing: Effectively reduces noise transmission, making spaces quieter and more comfortable.

🔥 Fire-Resistant Composition: Made from non-combustible stone wool, providing high fire safety standards.

💧 Moisture Control: Prevents water absorption, reducing the risk of mold and structural damage.

🛠️ Durable & Long-Lasting: Resistant to compression and deterioration, maintaining its effectiveness over time.

Engineered for Superior Performance

ThermoWool Roof Mattress is designed to offer exceptional insulation in various roofing systems. Whether for residential, commercial, or industrial buildings, it ensures high performance in thermal regulation, sound control, and fire safety. This product is easy to install and offers long-term reliability, making it the ideal choice for roofing insulation.

Technical Information

Technical Characteristics Symbol Indicator Unit Declared Value Tolerance Standard
Material MW MW - Mineralwool - EN 13162
Density / D ρ kg/m3 40 | 50 ± % 10 EN 1602
Length / l l mm 3000 | 5000 | 8000 ± % 2 EN 822
Width / b b mm 600 | 1200 ± % 1,5 EN 1822
Thermal Conductivity λD W/mK max 0,037 - EN 12939/12667
Thermal Resistance / Rd RD m²K/W 1,39 | 1,67 | 1,94 | 2,22 | 2,78 | 3,33 | 3,88 | 4,25 - EN 13162
Thickness / d dN mm 50 | 60 | 70 | 80 | 100 | 120 | 140 | 150 - EN 823
Class for Thickness Tolerances mm 'T4 -%3 or -3 mm * +%5 or +5mm * EN 823
Dimensional Stability DS(70-) ∆Ɛd % max 1 EN 1604
Water Vapour Permeability / MU MU µ - 1 EN 12086
Fire Reaction Class - RtF - A1 EN 13501
Air Flow Resistance / Afr Afr Afr - NPD EN 29053
Flatness / Smax Smax mm S6 - max 6 mm - EN 825
Squareness / Sb Sb mm/m S5 - max 5 mm/m - EN 824
Short Term Water Absorption / WS WP kg/m² ≤1 - EN 1609
Long Term Water Absorption / WL(P) WLP kg/m² ≤3 - EN 12087
Max. Usage Temperature - - °C +750 -
Packaging Material - - - PE Film -
Covering - - - Uncoated -