MINERAL STONEWOOL
Fire Door Board
ThermoWool Mineral Stonewool Door Fire Board is a Stonewool board specifically designed for use in fire doors, steel door inner and side areas, cold storage door interiors, and gate doors of industrial ovens. It is available in custom sizes and can be coated or uncoated based on specific requirements.
Key Features
✅ Fire Safety: Provides excellent fire resistance, making it ideal for fire doors and other critical safety applications.
✅ Custom Sizes: Produced in special sizes to meet the exact needs of each project.
🛡️ Durable and Reliable: Ensures long-lasting performance in demanding environments, offering high durability.
✅ Coated or Uncoated Options: Available as coated or uncoated according to the specific application requirements.
Ideal for a Variety of Applications
ThermoWool Mineral Stonewool Door Fire Board is perfect for use in various fire safety and insulation applications in buildings and industrial facilities.
Applications: Fire doors, steel door interiors and side areas, cold storage doors, industrial oven gate doors, and other fire safety applications where heat and fire resistance are essential.
Technical Information
| Technical Characteristics | Symbol | Indicator | Unit | Declared Value | Tolerance | Standard |
|---|---|---|---|---|---|---|
| Material | MW | MW | - | Mineralwool | - | EN 13162 |
| Density / D | - | ρ | kg/m³ | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 150 | ± % 10 | EN 1602 |
| Length / l | l | l | mm | 1200 (can be evaluated at the request of the manufacturer) | ± % 2 | EN 822 |
| Width / b | b | b | mm | 600 (can be evaluated at the request of the manufacturer) | ± % 1.5 | EN 1822 |
| Thermal Conductivity | λD | - | W/mK | max 0.037 | - | EN 12939/12667 |
| Thermal Resistance / Rd | RD | - | m²K/W | 0.83 | 1.11 | 1.39 | 1.67 | 1.94 | 2.22 | 2.78 | - | EN 13162 |
| Thickness / d | dN | dN | mm | 30 | 40 | 50 | 60 | 70 | 80 | 100 | - | EN 823 |
| Class for Thickness Tolerances | Tİ | - | mm | 'T4 | -%3 or -3 mm * +%5 or +5mm * | EN 823 |
| Dimensional Stability | DS(70-) | ∆Ɛd | % | max 1 | - | EN 1604 |
| Water Vapour Permeability / MU | MU | µ | - | 1 | - | EN 12086 |
| Fire Reaction Class | - | RtF | - | A1 | - | EN 13501 |
| Air Flow Resistance / Afr | Afr | Afr | - | NPD | - | EN 29053 |
| Flatness / Smax | Smax | Smax | mm | S6 - max 6 mm | - | EN 825 |
| Squareness / Sb | Sb | Sb | mm/m | S5 - max 5 mm/m | - | EN 824 |
| Short Term Water Absorption / WS | WP | WS | kg/m² | ≤1 | - | EN 1609 |
| Long Term Water Absorption / WL(P) | WLP | WL(P) | kg/m² | ≤3 | - | EN 12087 |
| Max. Usage Temperature | - | - | °C | +750 | - | - |
| Packaging Material | - | - | - | PE Film | - | - |
| Covering | - | - | - | Uncoated, Glasswool or Aluminium Foil Coated | - | - |