MINERAL STONEWOOL
Roof Mattress
ThermoWool Roof Mattress is a versatile insulation solution used in various roofing applications. It is suitable for cradle roofs, hipped roofs, snap roofs, and unutilized attic flooring. This product is also ideal for use between utilized roofs, rafters, or in horizontal installations without load. Additionally, ThermoWool Roof Mattress is perfect for metal and sandwich roofs, providing outstanding heat, sound, and fire insulation. It helps enhance the thermal efficiency of roofs, ensuring comfort, safety, and energy savings.
Key Features
✅ Advanced Thermal Insulation: Reduces heat loss, improves energy efficiency, and ensures optimal comfort in buildings.
✅ Excellent Soundproofing: Effectively reduces noise transmission, making spaces quieter and more comfortable.
🔥 Fire-Resistant Composition: Made from non-combustible stone wool, providing high fire safety standards.
💧 Moisture Control: Prevents water absorption, reducing the risk of mold and structural damage.
🛠️ Durable & Long-Lasting: Resistant to compression and deterioration, maintaining its effectiveness over time.
Engineered for Superior Performance
ThermoWool Roof Mattress is designed to offer exceptional insulation in various roofing systems. Whether for residential, commercial, or industrial buildings, it ensures high performance in thermal regulation, sound control, and fire safety. This product is easy to install and offers long-term reliability, making it the ideal choice for roofing insulation.
Technical Information
| Technical Characteristics | Symbol | Indicator | Unit | Declared Value | Tolerance | Standard |
|---|---|---|---|---|---|---|
| Material | MW | MW | - | Mineralwool | - | EN 13162 |
| Density / D | ρ | kg/m3 | 40 | 50 | ± % 10 | EN 1602 | |
| Length / l | l | mm | 3000 | 5000 | 8000 | ± % 2 | EN 822 | |
| Width / b | b | mm | 600 | 1200 | ± % 1,5 | EN 1822 | |
| Thermal Conductivity | λD | W/mK | max 0,037 | - | EN 12939/12667 | |
| Thermal Resistance / Rd | RD | m²K/W | 1,39 | 1,67 | 1,94 | 2,22 | 2,78 | 3,33 | 3,88 | 4,25 | - | EN 13162 | |
| Thickness / d | dN | mm | 50 | 60 | 70 | 80 | 100 | 120 | 140 | 150 | - | EN 823 | |
| Class for Thickness Tolerances | Tİ | mm | 'T4 | -%3 or -3 mm * +%5 or +5mm * | EN 823 | |
| Dimensional Stability | DS(70-) | ∆Ɛd | % | max 1 | EN 1604 | |
| Water Vapour Permeability / MU | MU | µ | - | 1 | EN 12086 | |
| Fire Reaction Class | - | RtF | - | A1 | EN 13501 | |
| Air Flow Resistance / Afr | Afr | Afr | - | NPD | EN 29053 | |
| Flatness / Smax | Smax | mm | S6 - max 6 mm | - | EN 825 | |
| Squareness / Sb | Sb | mm/m | S5 - max 5 mm/m | - | EN 824 | |
| Short Term Water Absorption / WS | WP | kg/m² | ≤1 | - | EN 1609 | |
| Long Term Water Absorption / WL(P) | WLP | kg/m² | ≤3 | - | EN 12087 | |
| Max. Usage Temperature | - | - | °C | +750 | - | |
| Packaging Material | - | - | - | PE Film | - | |
| Covering | - | - | - | Uncoated | - |