MINERAL STONEWOOL
Ship Board
ThermoWool Mineral Stonewool Ship Boards are high-performance rock wool boards designed for heat, sound insulation, and fire safety in marine applications. These boards are ideal for use in ship hulls, marine construction, ship interior installations, cofferdam walls, fire compartments, and fire safety doors.
Key Features
✅ Superior Heat Insulation: Provides excellent thermal insulation, ensuring energy efficiency and temperature control in marine environments.
✅ Soundproofing Properties: Effectively reduces noise transmission, contributing to a more comfortable and quieter onboard environment.
🔥 Fire Safety: Meets strict fire safety standards, providing enhanced protection in critical areas of the ship.
✅ Versatile Applications: Suitable for use in ship hulls, interior spaces, fire compartments, and fire safety doors, offering comprehensive protection.
🛠️ Easy to Install: Simple to install, providing seamless integration into various shipbuilding and installation processes.
Ideal for a Variety of Applications
ThermoWool Mineral Stonewool Ship Boards are the ideal solution for heat, sound, and fire insulation in marine environments, ensuring safety, efficiency, and comfort aboard ships.
Applications: Ship hulls, marine construction, ship interior installations, cofferdam walls, fire compartments, fire safety doors, and other high-performance marine insulation needs.
Technical Information
| Technical Characteristics | Symbol | Indicator | Unit | Declared Value | Tolerance | Standard |
|---|---|---|---|---|---|---|
| Material | MW | MW | - | Mineralwool | - | EN 13162 |
| Density / D | - | ρ | kg/m³ | 30 | 40 | 50 | 60 | 110 | 140 | 150 | ± % 10 | EN 1602 |
| Length / l | l | l | mm | 1200 | ± % 2 | EN 822 |
| Width / b | b | b | mm | 600 | ± % 1.5 | EN 1822 |
| Thermal Conductivity | λD | - | W/mK | max 0.037 | - | EN 12939/12667 |
| Thermal Resistance / Rd | RD | - | m²K/W | 0.83 | 1.11 | 1.39 | 1.67 | - | EN 13162 |
| Thickness / d | dN | dN | mm | 30 | 40 | 50 | 60 | - | EN 823 |
| Class for Thickness Tolerances | Tİ | - | mm | 'T4 | -%3 or -3 mm * +%5 or +5mm * | EN 823 |
| Dimensional Stability | DS(70-) | ∆Ɛd | % | max 1 | - | EN 1604 |
| Water Vapour Permeability / MU | MU | µ | - | 1 | - | EN 12086 |
| Fire Reaction Class | - | RtF | - | A1 | - | EN 13501 |
| Air Flow Resistance / Afr | Afr | Afr | - | NPD | - | EN 29053 |
| Flatness / Smax | Smax | Smax | mm | S6 - max 6 mm | - | EN 825 |
| Squareness / Sb | Sb | Sb | mm/m | S5 - max 5 mm/m | - | EN 824 |
| Short Term Water Absorption / WS | WP | WS | kg/m² | ≤1 | - | EN 1609 |
| Long Term Water Absorption / WL(P) | WLP | WL(P) | kg/m² | ≤3 | - | EN 12087 |
| Max. Usage Temperature | - | - | °C | +750 | - | - |
| Packaging Material | - | - | - | PE Film | - | - |
| Covering | - | - | - | Uncoated | - | - |